Skip to main content

The data and outputs

The British Columbia Shore Station Oceanographic Program (BCSOP) has collected daily sea surface temperature and salinity at BC lightstations since 1914. Samples are taken by bucket, near daytime high tide, using the same method for decades so the record stays consistent. CIOOS Pacific serves the data through ERDDAP, a data server where every request is a URL.

I retrieved daily temperature from 1991 onward with the rerddap package and logged the exact request.

Show code
library(rerddap)
info_obj <- info("BCSOP_daily", url = "https://data.cioospacific.ca/erddap/")
raw <- tabledap(info_obj,
                fields = c("profile", "latitude", "longitude", "time", "TEMPTC01"),
                "time>=1991-01-01",
                url = "https://data.cioospacific.ca/erddap/")

I kept the 12 stations with at least 80% daily coverage over 1991 to 2020, the current climate normal period. That matches the number of stations the program says are currently active. Five stations with shorter records were excluded.

Outputs and metadata

File Contents
bc_lightstation_sst_qc.nc NetCDF: temperature plus five QC flag variables
bc_lightstation_sst_qc.csv The same data, one row per station-day
data_dictionary.csv Variable definitions, units, CF standard names, and allowed values

Two metadata conventions do different jobs:

  • CF conventions describe what the numbers are: units, standard names, and how coordinates and flags link to data.
  • ACDD describes the dataset: title, summary, creator, licence, and coverage. These are the attributes catalogues harvest for discovery.

The NetCDF uses the CF “orthogonal multidimensional” layout for time series, where every station shares one time axis. Each flag variable uses a CF standard name such as spike_test_quality_flag, and the temperature variable lists them in ancillary_variables.

I checked the file with the IOOS Compliance Checker. It passes all CF-1.8 checks. For ACDD-1.3, the only remaining items are four optional vertical attributes. I left these out on purpose: the data are surface samples with no depth variable, and adding them without one triggers a different warning. The full report is in docs/compliance_report.txt.

How to reproduce

The full workflow is on GitHub. From the repository folder:

Rscript tests/test_qartod.R      # unit tests for the QC functions
Rscript R/01_download.R          # retrieve data from CIOOS Pacific ERDDAP
Rscript R/02_qc.R                # run QARTOD tests, write QC summary and plots
Rscript R/03_write_outputs.R     # NetCDF, CSV, and data dictionary
Rscript R/04_map.R               # animated map and heatmap
Rscript R/06_banner.R            # banner stripes for this page
compliance-checker --test=cf:1.8 --test=acdd:1.3 data/output/bc_lightstation_sst_qc.nc
quarto render                    # this site, including the interactive map

R/05_interactive_map.R has no separate step: it runs automatically during quarto render, which builds the interactive map on the Heatwave page.

Data, code, and licence

  • Archived release: Zenodo, doi.org/10.5281/zenodo.24326157
  • Source data: British Columbia Shore Station Oceanographic Program, Institute of Ocean Sciences, Fisheries and Oceans Canada, via CIOOS Pacific. Contains information licensed under the Open Government Licence - Canada.
  • Basemaps: Natural Earth (animated map); Esri World Gray Canvas (interactive map).
  • Code: MIT licence. Derived data: CC-BY-4.0.